Contact

Mini-Extruder Information

Blue washed banner of scientist looking into glass jar

Avanti Mini Extruder allows researchers and scientists to prepare large, unilamellar vesicles by extrusion in an efficient manner.

Mini Extruder on a transparent background

Convenient

  • Prepare large, unilamellar vesicles (LUVs) by extrusion in an easy, rapid, and efficient manner
  • Design allows for the rapid cleaning of all wetted parts, reducing “down-time” between production of vesicles from different lipid species
  • Generate uniform populations of unilamellar liposomes without the use of solvents or detergents
  • Vesicle size readily controlled by polycarbonate membrane selection

Affordable 

The Avanti Mini-Extruder is constructed of stainless steel and Teflon; the new design is guaranteed to give years of trouble-free service and is available for a fraction of the cost of a larger extruder.

  • Available for a fraction of the cost of a larger extruder
  • All parts/replacement parts are available from Avanti
  • Complete set includes: Mini Extruder, Heating Block, 2 O-Rings, 2 Gas Tight syringes, 100 Polycarbonate Membranes, 100 Filter supports

Flexible

Placing the stabilizer block-extruder assembly on a hot plate achieves rapid temperature control for lipids that have transition temperatures above room temperature.

  • Optional heating block allows the extrusion of vesicles at elevated temperatures, which is critical for the successful production of vesicles from phospholipids with a phase transition temperature above room temperature
  • Generate unilamellar liposomes ranging from 30nm-1 µm when assembled with appropriate polycarbonate membrane
  • Useful for a wide variety of lipid composition
  • Interchangeable with 250 µL and 1 mL syringes

Reliable

The particle size distribution of unilamellar vesicles prepared by extrusion is a function of the number of passes through the extruder membrane.

Mini Extruder from Avanti Research

Equipment Graph by Avanti Research

 

 

 

 

 

 

Hydrated lipid will initially form large, multilamellar vesicles. After the initial pass through a membrane, the particle size distribution will tend towards bimodal. After sufficient passes through the membrane, a unimodal, normal distribution is obtained. A minimum of eleven passes through the extruder membrane is recommended for most lipids.

Heating Block Graph

 

 

 

 

 

 

Placing the heating block assembly on a hot plate achieves rapid temperature control for lipids that have transition temperatures above room temperature.

 

 

 

 

 

 

 

 

Products

Instructions

  • Assembly Detailed instructions on assembly of the Avanti Mini-Extruder
  • Extrusion Detailed instructions on extrusion of liposomes
  • Cleaning Detailed instructions on cleaning of syringes